AOD angle Wedge 6.625"(single side scan Wedge) pipe ranger coverable - 141.3mm (5.563")-168.3mm (6.6
AOD angle Wedge 6.625"(single side scan Wedge) pipe ranger coverable - 141.3mm (5.563")-168.3mm (6.625") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 4"(single side scan Wedge) pipe ranger coverable 88.9mm(3.5")-101.6mm(4")
AOD angle Wedge 4"(single side scan Wedge) pipe ranger coverable 88.9mm(3.5")-101.6mm(4") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 4.5"(single side scan Wedge) pipe ranger coverable 101.6mm (4")-114.3mm (4.5")
AOD angle Wedge 4.5"(single side scan Wedge) pipe ranger coverable 101.6mm (4")-114.3mm (4.5") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 5.563"(single side scan Wedge) pipe ranger coverable 114.3mm(4.5")-141.3mm (5.563")
AOD angle Wedge 5.563"(single side scan Wedge) pipe ranger coverable 114.3mm(4.5")-141.3mm (5.563") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 2.875" (single side scan Wedge)Tube ranger coverable 60.3mm(2.375")-73.0mm(2.875")
Wedge (55deg) for A101 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 2.375"(single side scan Wedge) Tube ranger coverable 50.8mm (2")-60.3mm (2.375")
Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
Flat angle Wedge (single side scan Wedge)
Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
Flat 0degree Wedge
Wedge (0deg) for A10 phased array probe - Designed for linear scanning at 0 degree using 0deg nominal angle Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 8.625" (Dual Scan Wedge set)
pipe ranger coverable - 168.3mm(6.625")-219.0mm(8.625") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 4.5" (Dual Scan Wedge set)
AOD angle Wedge 4.5" (Dual Scan Wedge set) pipe ranger coverable 101.6mm (4")-114.3mm (4.5") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 4" (Dual Scan Wedge set)
AOD angle Wedge 4" (Dual Scan Wedge set) pipe ranger coverable 88.9mm(3.5")-101.6mm(4") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 3.5" (Dual Scan Wedge set)
AOD angle Wedge 3.5" (Dual Scan Wedge set) pipe ranger coverable 73.0mm(2.875")-88.9mm (3.5") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 2.875" (Dual Scan Wedge set)
AOD angle Wedge 2.875" (Dual Scan Wedge set) Tube ranger coverable 60.3mm(2.375")-73.0mm(2.875") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
Flat angle Wedge (Dual Scan Wedge set)
Flat angle Wedge (Dual Scan Wedge set) Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 2.375" (Dual Scan Wedge set)
AOD angle Wedge 2.375" (Dual Scan Wedge set) Tube ranger coverable 50.8mm (2")-60.3mm (2.375") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 24" (single side scan Wedge) pipe ranger coverable - 406.4mm(16")-609.6mm(24")
AOD angle Wedge 24" (single side scan Wedge) pipe ranger coverable - 406.4mm(16")-609.6mm(24") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 12.75"(single side scan Wedge) pipe ranger coverable - 273.0mm(10.75")-323.8mm(12.75
AOD angle Wedge 12.75"(single side scan Wedge) pipe ranger coverable - 273.0mm(10.75")-323.8mm(12.75") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
Twenty Seven (27) set dual side scan A10 Series Wedges with AODs 2" to 24" & Flat angel, one 0 degree Wedge
A10 Series Wedges for Tube till Pipes Twenty Seven (27) set dual side scan A10 Series Wedges with AODs 2" to 24" & Flat angel, one 0 degree Wedge. Set include Each 2 number from below specifications 1-Flat 0degree Wedge 2-Flat angle Wedge 3,AOD angle Wedge 2.375" Tube ranger coverable -50.8mm (2")-60.3mm (2.375") 4,AOD angle Wedge 2.875" Tube ranger coverable-60.3mm(2.375")-73.0mm(2.875") 5,AOD angle Wedge 3.5" pipe ranger coverable-73.0mm(2.875")-88.9mm (3.5") 6,AOD angle Wedge 4" pipe ranger coverable-88.9mm(3.5")-101.6mm(4") 7,AOD angle Wedge 4.5" pipe ranger coverable-101.6mm (4")-114.3mm (4.5") 8,AOD angle Wedge 5.563" pipe ranger coverable-114.3mm(4.5")-141.3mm (5.563") 8,AOD angle Wedge 5.563" pipe ranger coverable-114.3mm(4.5")-141.3mm (5.563") 9,AOD angle Wedge 6.625" pipe ranger coverable - 141.3mm (5.563")-168.3mm (6.625") 10,AOD angle Wedge 8.625" pipe ranger coverable - 168.3mm(6.625")-219.0mm(8.625") 11,AOD angle Wedge 10.75" pipe ranger coverable - 219.0mm(8.625")-273.0mm(10.75") 12,AOD angle Wedge 12.75" pipe ranger coverable - 273.0mm(10.75")-323.8mm(12.75") 13,AOD angle Wedge 16" pipe ranger coverable - 323.8mm(12.75")-406.4mm(16") 14,AOD angle Wedge 24" pipe ranger coverable - 406.4mm(16")-609.6mm(24") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
Fourteen(14) set single side scan A10 Series Wedges with AODs 2" to 24" & Flat angel, 0 degree Wedge
A10 Series Wedges for Tube till Pipes : Fourteen(14) set single side scan A10 Series Wedges with AODs 2" to 24" & Flat angel, 0 degree Wedge. Set include Each 1 number from below specifications 1-Flat 0degree Wedge 2-Flat angle Wedge 3,AOD angle Wedge 2.375" Tube ranger coverable -50.8mm (2")-60.3mm (2.375") 4,AOD angle Wedge 2.875" Tube ranger coverable-60.3mm(2.375")-73.0mm(2.875") 5,AOD angle Wedge 3.5" pipe ranger coverable-73.0mm(2.875")-88.9mm (3.5") 6,AOD angle Wedge 4" pipe ranger coverable-88.9mm(3.5")-101.6mm(4") 7,AOD angle Wedge 4.5" pipe ranger coverable-101.6mm (4")-114.3mm (4.5") 8,AOD angle Wedge 5.563" pipe ranger coverable-114.3mm(4.5")-141.3mm (5.563") 8,AOD angle Wedge 5.563" pipe ranger coverable-114.3mm(4.5")-141.3mm (5.563") 9,AOD angle Wedge 6.625" pipe ranger coverable - 141.3mm (5.563")-168.3mm (6.625") 10,AOD angle Wedge 8.625" pipe ranger coverable - 168.3mm(6.625")-219.0mm(8.625") 11,AOD angle Wedge 10.75" pipe ranger coverable - 219.0mm(8.625")-273.0mm(10.75") 12,AOD angle Wedge 12.75" pipe ranger coverable - 273.0mm(10.75")-323.8mm(12.75") 13,AOD angle Wedge 16" pipe ranger coverable - 323.8mm(12.75")-406.4mm(16") 14,AOD angle Wedge 24" pipe ranger coverable - 406.4mm(16")-609.6mm(24") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 24" (Dual Scan Wedge set)
AOD angle Wedge 24" (Dual Scan Wedge set) pipe ranger coverable - 406.4mm(16")-609.6mm(24") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 16" (Dual Scan Wedge set)
AOD angle Wedge 16" (Dual Scan Wedge set) pipe ranger coverable - 323.8mm(12.75")-406.4mm(16") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 12.75" (Dual Scan Wedge set)
AOD angle Wedge 12.75" (Dual Scan Wedge set) pipe ranger coverable - 273.0mm(10.75")-323.8mm(12.75") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 5.563" (Dual Scan Wedge set)
AOD angle Wedge 5.563" (Dual Scan Wedge set) pipe ranger coverable 114.3mm(4.5")-141.3mm (5.563") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 16"(single side scan Wedge) pipe ranger coverable - 323.8mm(12.75")-406.4mm(16")
AOD angle Wedge 16"(single side scan Wedge) pipe ranger coverable - 323.8mm(12.75")-406.4mm(16") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 10.75"(single side scan Wedge) pipe ranger coverable - 219.0mm(8.625")-273.0mm(10.75
AOD angle Wedge 10.75"(single side scan Wedge) pipe ranger coverable - 219.0mm(8.625")-273.0mm(10.75") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 8.625"(single side scan Wedge) pipe ranger coverable - 168.3mm(6.625")-219.0mm(8.625
AOD angle Wedge 8.625"(single side scan Wedge) pipe ranger coverable - 168.3mm(6.625")-219.0mm(8.625") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
Nineteen(19) set DUAL side scan A10 Series Wedges with AODs 4.5" to 24" & tow Flat angel, one 0 degree Wedge.
A10 Series Wedges for Pipe Nineteen(19) set DUAL side scan A10 Series Wedges with AODs 4.5" to 24" & tow Flat angel, one 0 degree Wedge. Set include Each 2 number from below specifications 1-Flat 0degree Wedge 2-Flat angle Wedge 3,AOD angle Wedge 5.563" pipe ranger coverable-114.3mm(4.5")-141.3mm (5.563") 4,AOD angle Wedge 5.563" pipe ranger coverable-114.3mm(4.5")-141.3mm (5.563") 5,AOD angle Wedge 6.625" pipe ranger coverable - 141.3mm (5.563")-168.3mm (6.625") 6,AOD angle Wedge 8.625" pipe ranger coverable - 168.3mm(6.625")-219.0mm(8.625") 7,AOD angle Wedge 10.75" pipe ranger coverable - 219.0mm(8.625")-273.0mm(10.75") 8,AOD angle Wedge 12.75" pipe ranger coverable - 273.0mm(10.75")-323.8mm(12.75") 9,AOD angle Wedge 16" pipe ranger coverable - 323.8mm(12.75")-406.4mm(16") 10,AOD angle Wedge 24" pipe ranger coverable - 406.4mm(16")-609.6mm(24") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 3.5"(single side scan Wedge) pipe ranger coverable 73.0mm(2.875")-88.9mm (3.5")
AOD angle Wedge 3.5"(single side scan Wedge) pipe ranger coverable 73.0mm(2.875")-88.9mm (3.5") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
Ten(10) set single side scan A10 Series Wedges with AODs 4.5" to 24" & Flat angel, 0 degree Wedge.
A10 Series Wedges for Pipe Ten(10) set single side scan A10 Series Wedges with AODs 4.5" to 24" & Flat angel, 0 degree Wedge. Set include Each 1 number from below specifications 1-Flat 0degree Wedge 2-Flat angle Wedge 3,AOD angle Wedge 5.563" pipe ranger coverable-114.3mm(4.5")-141.3mm (5.563") 4,AOD angle Wedge 5.563" pipe ranger coverable-114.3mm(4.5")-141.3mm (5.563") 5,AOD angle Wedge 6.625" pipe ranger coverable - 141.3mm (5.563")-168.3mm (6.625") 6,AOD angle Wedge 8.625" pipe ranger coverable - 168.3mm(6.625")-219.0mm(8.625") 7,AOD angle Wedge 10.75" pipe ranger coverable - 219.0mm(8.625")-273.0mm(10.75") 8,AOD angle Wedge 12.75" pipe ranger coverable - 273.0mm(10.75")-323.8mm(12.75") 9,AOD angle Wedge 16" pipe ranger coverable - 323.8mm(12.75")-406.4mm(16") 10,AOD angle Wedge 24" pipe ranger coverable - 406.4mm(16")-609.6mm(24") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)
AOD angle Wedge 10.75" (Dual Scan Wedge set)
pipe ranger coverable - 219.0mm(8.625")-273.0mm(10.75") Wedge (55deg) for A10 phased array probe - Designed for azimuthal scanning from 40 to 70 degree using 55deg nominal angle, Stainless steel screw receptacles provide a firm anchoring of probe to wedge Wedges are available with irrigation, holes for mounting a scanners and carbide pins for wear resistance Wedges are designed to perform manual or automated scans (scanners)